Description
Operating Wavelength(nm) | 1260-1650 | Inspected date | 2015 -12-8 |
---|---|---|---|
P/N | PLC-B-1X8 | S/N | 1512080087 |
Fiber type | G657A | Fiber length(m) | 1.5 |
Connector type | None | Package dimension(mm) | 4x4 x40 |
Storage temperature | -40+~85°C | Operating temperature | -40+~85°C |
Item | IL(dB) | PDL(dB) | RL(dB) |
Wavelength(nm)n | @1310 @1550 | @1310 @1550 | @1310 @1550 |
Spec | MAX.10.20 | MAX.0.15 | Pass - Pass |
Port 1 | 10.11 - 9.47 | 0.02 - 0.07 | Pass - Pass |
Port 2 | 9.82 - 9.51 | 0.02 - 0.05 | Pass - Pass |
Port 3 | 9.46 - 9.72 | 0.03 - 0.07 | Pass - Pass |
Port 4 | 10.05 - 10.09 | 0.03 - 0.07 | Pass - Pass |
Port 5 | 9.59 - 10.12 | 0.06 - 0.01 | Pass - Pass |
Port 6 | 9.95 - 10.07 | 0.07 - 0.08 | Pass - Pass |
Port 7 | 9.81 - 9.99 | 0.02 - 0.04 | Pass - Pass |
Port 8 | 10.02 - 9.91 | 0.06 - 0.07 | Pass - Pass |
Input | N/A | ||
MAX | 10.11 - 10.12 | 0.07 - 0.08 | N/A |
MIN | 9.46 - 9.47 | 0.02 - 0.01 | N/A |
Average | 9.85 - 9.86 | 0.04 - 0.06 | N/A |
Uniformity(.8dB) | 0.65 - 0.65 | Directivity(dB) | >55 |